SensMini M4 Configuration Tool




Sign In


Account:
Password:
AnaSystem SensMini M4
AnaSystem SensMini M4
Renew Existing User Password
AnaSystem SensMini M4
New account:
New password:
Confirm password:







Device Status
Device type SensMini M4
Mobile state NaN
Mobile signal strength NaN
Mobile client IP 0.0.0.0
Computer time 0.0.0 00:00:00
SensMini M4 time 0.0.0 00:00:00



General Parameter Settings


Parameter Current value New value
System
Recording interval
Sleeping interval (times Recording interval)
Auto send interval (second)
Power saving mode Enable Disable
DI input power on DI 0 DI 1
RS-232 power Enable Disable
RS-485_1 power Enable Disable
RS-485_2 power Enable Disable
ADC power Enable Disable
Bat. LVD threshold (Volt)
Bat. LVD reboot difference > 0.5 (Volt)
DI status record Enable Disable
Mobile transfer protocol Senslink ModbusTCP
Wired LAN
MAC address
IP address
IP mask
Gateway
DNS
Time zones
Wireless setting
Mobile module Enable Disable
Mobile set up interval (Recording interval x N times)
APN
Senslink cloud communication
Server / Client Server Client
(Client) Group ID
(Client) Serial ID
Server mode
LAN listen port
3G listen port
Client mode
Priority connection LAN Mobile
Senslink server IP
Senslink port
External device setting
(COM1)RS-485_1 baudrate (bps)
(COM1)RS-485_1 Parity-Data-Stop bit
(COM2)RS-485_2 baudrate (bps)
(COM2)RS-485_2 Parity-Data-Stop bit
(COM3)RS-232 baudrate (bps)
(COM3)RS-232 Parity-Data-Stop bit
Wake-up elapsed time (sec)
Device connection tolerance (sec)


Reset Parameter File


Reset the parameters to the default values Reboot SensMini M4





COM Port Protocol Settings


COM 1 (RS-485) COM 2 (RS-485) COM 3 (RS-232)
Enable Device No. COM port Command Start byte Measurements Item data bytes Byte order No receive
0 Onboard Onboard Onboard Onboard Onboard Onboard Onboard
1
2
3
4
5


Onboard AI Parameters


ADC mode AI 0 AI 1 AI 2 AI 3
Differential
Single-ended





Software Node Settings


Enable Software node Device No. No. of measurements Formula ID Filter Power source
DO_0
Power source
DO_1
Ch00
Ch01
Ch02
Ch03
Ch04
Ch05
Ch06
Ch07
Ch08
Ch09
Ch10
Ch11
Ch12
Ch13
Ch14
Ch15
Ch16
Ch17
Ch18
Ch19
Ch20
Ch21
Ch22
Ch23
Ch24
Ch25
Ch26
Ch27
Ch28
Ch29
Ch30
Ch31



DO Mode selection
DO_0 / DO_1 mode selection

[Mode 0] Remote Control / [Mode 1] Always On / [Mode 2] Follow Recording Interval
DO_0 enable DO_1 enable

[Mode 3] DO Status Changed with AI
Enable DO NO. Software node reference Threshold low Threshold high Mode
DO_0
DO_0
DO_0
DO_0
DO_0
DO_1
DO_1
DO_1
DO_1
DO_1


Formula1 Coefficients


Formula ID Coef. a Coef. b Coef. c


Formula2 Coefficients


Formula ID Coef. a Coef. b





Onboard Original Channel Values


00 01 02 03 04
AI0 AI1 AI2 AI3 DI0 counter
05 06 07 08 09
DI1 counter DI0 status DI1 status DO0 status DO1 status
10 11 12 13 14
Battery voltage External voltage Ch00 0-0 hour (Display)
15 16 17 18 19
Mobile state Mobile Signal strength



Software Node Real-Time Values


00 01 02 03
04 05 06 07
08 09 10 11
12 13 14 15
16 17 18 19
20 21 22 23
24 25 26 27
28 29 30 31


Read History Record from SD Card
(Chrome, Firefox)


Year Month Day Total day(s)






Firmware Version
SensMini M4 GUID No data
Current version 000
Attention:
After entering firmware update process
(Step 1)Wait 30 seconds
(Step 2)Use Tftp client to transfer the firmware file to M4
(Step 3)Reload the web page in 5 seconds



Read Parameter File / Show Debug Messages


Read the parameter file from SD card Show debug messages(Chrome, Firefox)